CS-21 Xist Thermal Predictions of Horizontal Shellside Condensation with Subcooling
October 10, 2018
HTRI collected data in a horizontal E-shell exchanger with vertical-cut baffles, obtaining varying degrees of subcooling at the exchanger outlet for water, n-pentane, p-xylene, and a binary mixture of n-pentane/p-xylene. Liquid level measurements along the length of the exchanger confirmed the presence of shellside flooding. Xist predicted the heat transfer area...
Read More
-
TT-7 Modeling flooding in horizontal tubeside condensers
January 26, 2017
Component: Xist Date posted: 7 October 2008 Last updated: 27 May 2025 NOTE: Guidance in this TechTip also applies to horizontal shellside condensers. Although Xist does not include an option to specify the flooded condensate level for horizontal tubeside condensers, you can use the incremental Xist results to determine the approximate flooded...